Skip to content
AnsweringExams.Com
  • Home
  • Contact Us / Report Error
  • Disclaimer

Design of Concrete Structures

Maximum percentage reinforcement in case of slabs is limited to___________________?

August 12, 2021January 12, 2019 by admin
Maximum percentage reinforcement in case of slabs is limited to___________________?

A. 2
B. 4
C. 6
D. 8

Categories Design of Concrete Structures, MCQs / Q&A

The minimum cover to the ties or spirals should not be less than________________?

August 12, 2021January 12, 2019 by admin
The minimum cover to the ties or spirals should not be less than________________?

A. 15 mm
B. 20 mm
C. 25 mm
D. 50mm

Categories Design of Concrete Structures, MCQs / Q&A

The limits of percentage p of the longitudinal reinforce-ment in a column is given by_____________?

August 12, 2021January 12, 2019 by admin
The limits of percentage p of the longitudinal reinforce-ment in a column is given by_____________?

A. 0.15% to 2%
B. 0.8% to 4%
C. 0.8% to 6%
D. 0.8% to 8%

Categories Design of Concrete Structures, MCQs / Q&A

The main reason for providing number of reinforcing bars at a support in a simply supported beam is to resist in that zone_________________?

August 12, 2021January 12, 2019 by admin
The main reason for providing number of reinforcing bars at a support in a simply supported beam is to resist in that zone_________________?

A. compressive stress
B. shear stress
C. bond stress
D. tensile stress

Categories Design of Concrete Structures, MCQs / Q&A

When shear stress exceeds the permissible limit in a slab, then it is reduced by____________?

August 12, 2021January 12, 2019 by admin
When shear stress exceeds the permissible limit in a slab, then it is reduced by____________?

A. increasing the depth
B. providing shear reinforcement
C. using high strength steel
D. using thinner bars but more in number

Categories Design of Concrete Structures, MCQs / Q&A

The permissible diagonal tensile stress in reinforced brick work is_____________?

August 12, 2021January 12, 2019 by admin
The permissible diagonal tensile stress in reinforced brick work is_____________?

A. about 0.1 N/mm2
B. zero
C. 0.3 N/mm2 to 0.7 N/mm2
D. about 1.0 N/mm2

Categories Design of Concrete Structures, MCQs / Q&A

If the size of panel in a flat slab is 6m x 6m, then as per Indian Standard Code, the widths of column strip and middle strip are__________________?

August 12, 2021January 12, 2019 by admin
If the size of panel in a flat slab is 6m x 6m, then as per Indian Standard Code, the widths of column strip and middle strip are__________________?

A. 3.0 m and 1.5 m
B. 1.5 m and 3.0 m
C. 3.0 m and 3.0 m
D. 1.5 m and 1.5 m

Categories Design of Concrete Structures, MCQs / Q&A

Half of the main steel in a simply supported slab is bent up near the support at a distance of x from the center of slab bearing where x is equal to________________?

August 12, 2021January 12, 2019 by admin
Half of the main steel in a simply supported slab is bent up near the support at a distance of x from the center of slab bearing where x is equal to________________?

A. 1/3
B. 1/5
C. 1/7
D. 1/10
where 1 is the span

Categories Design of Concrete Structures, MCQs / Q&A

In working stress design, permissible bond stress in the case of deformed bars is more than that in plain bars by_______________?

August 12, 2021January 12, 2019 by admin
In working stress design, permissible bond stress in the case of deformed bars is more than that in plain bars by_______________?

A. 10%
B. 20%
C. 30%
D. 40%

Categories Design of Concrete Structures, MCQs / Q&A

Ratio of permissible stress in direct compression and bending compression is______________?

August 12, 2021January 12, 2019 by admin
Ratio of permissible stress in direct compression and bending compression is______________?

A. less than 1
B. between 1 and 1.5
C. between 1.5 and 2.0
D. greater than 2

Categories Design of Concrete Structures, MCQs / Q&A
Older posts
Newer posts
← Previous Page1 … Page6 Page7 Page8 … Page14 Next →
© 2025 AnsweringExams.Com • Built with GeneratePress