Our website is made possible by displaying online advertisements to our visitors. Please consider supporting us by whitelisting our website.

Chemical Engineering Basics

Which of the following transducers is most commonly used for the measurement of shock and vibration ?

Question: Which of the following transducers is most commonly used for the measurement of shock and vibration ?
[A].

Linear variable differential transducer (LVDT)

[B].

Dial gauge

[C].

Accelerometer

[D].

none of these

Answer: Option C

Explanation:

No answer description available for this question.

Which of the following transducers is most commonly used for the measurement of shock and vibration ? Read More »

CHEMICAL ENGINEERING, Chemical Engineering Basics

For dynamic strain measurement, the wheatstone bridge used is of __________ type.

Question: For dynamic strain measurement, the wheatstone bridge used is of __________ type.
[A].

voltage sensitive null

[B].

voltage sensitive deflected

[C].

current sensitive deflected

[D].

none of these

Answer: Option B

Explanation:

No answer description available for this question.

For dynamic strain measurement, the wheatstone bridge used is of __________ type. Read More »

CHEMICAL ENGINEERING, Chemical Engineering Basics

__________ circuit is most commonly used to measure strain with the help of a strain gauge.

Question: __________ circuit is most commonly used to measure strain with the help of a strain gauge.
[A].

Ballast

[B].

Voltage balancing potentiometric

[C].

Simple current sensitive

[D].

none of these

Answer: Option B

Explanation:

No answer description available for this question.

__________ circuit is most commonly used to measure strain with the help of a strain gauge. Read More »

CHEMICAL ENGINEERING, Chemical Engineering Basics

Cascade control is

Question: Cascade control is
[A].

the continuous adjustment of the set point index of an automatic control loop by a primary (master) controller.

[B].

used when changes in process conditions cause serious upsets in the controlled variable.

[C].

useful to control flow from temperature.

[D].

all ‘a’, ‘b’ & ‘c’.

Answer: Option D

Explanation:

No answer description available for this question.

Cascade control is Read More »

CHEMICAL ENGINEERING, Chemical Engineering Basics

Floating control action

Question: Floating control action
[A].

moves the final control element at constant speed in either direction in response to an error signal.

[B].

changes the position of the final control element from on to off.

[C].

is used to counteract rapid load changes.

[D].

none of these.

Answer: Option A

Explanation:

No answer description available for this question.

Floating control action Read More »

CHEMICAL ENGINEERING, Chemical Engineering Basics

On-off control

Question: On-off control
[A].

fully opens the final control element, when the measured variable is below the set point.

[B].

fully closes the final control element, when the measured variable is above the set point.

[C].

is a two position control (fully open or fully closed) control adequate to control a process with slow reaction and minimum dead time or transfer lag.

[D].

none of these.

Answer: Option C

Explanation:

No answer description available for this question.

On-off control Read More »

CHEMICAL ENGINEERING, Chemical Engineering Basics

A controller action in which there is a con-tinous relation between the values of controlled variable and the rate of change of conrolled output signal is called the __________ action.

Question: A controller action in which there is a con-tinous relation between the values of controlled variable and the rate of change of conrolled output signal is called the __________ action.
[A].

proportional

[B].

integral

[C].

derivative

[D].

none of these

Answer: Option B

Explanation:

No answer description available for this question.

A controller action in which there is a con-tinous relation between the values of controlled variable and the rate of change of conrolled output signal is called the __________ action. Read More »

CHEMICAL ENGINEERING, Chemical Engineering Basics

Difference at any instant between the value of the controlled variable and the set point is called the

Question: Difference at any instant between the value of the controlled variable and the set point is called the
[A].

deviation

[B].

derivative time

[C].

error ratio

[D].

differential gap

Answer: Option A

Explanation:

No answer description available for this question.

Difference at any instant between the value of the controlled variable and the set point is called the Read More »

CHEMICAL ENGINEERING, Chemical Engineering Basics

Device used as a standard for the calibration of pressure gauges is a

Question: Device used as a standard for the calibration of pressure gauges is a
[A].

bellow

[B].

diaphragm

[C].

dead weight pressure tester

[D].

mercury manometer

Answer: Option C

Explanation:

No answer description available for this question.

Device used as a standard for the calibration of pressure gauges is a Read More »

CHEMICAL ENGINEERING, Chemical Engineering Basics