A valve which maintains a constant degree of superheat at the end of the evaporator coil, is called

Question: A valve which maintains a constant degree of superheat at the end of the evaporator coil, is called
[A].

automatic expansion valve

[B].

high side float valve

[C].

thermostatic expansion valve

[D].

low side float valve

Answer: Option D

Explanation:

No answer description available for this question.

A thermostatic expansion valve in a refrigeration system

Question: A thermostatic expansion valve in a refrigeration system
[A].

ensures the evaporator completely filled with refrigerant of the load

[B].

is suitable only for constant load systems

[C].

maintains different temperatures in evaporator in proportion to load

[D].

none of the above

Answer: Option A

Explanation:

No answer description available for this question.

Compute the horizontal and vertical components of force at pin B. The belt is subjected to a tension of T=100 N and passes over each of the three pulleys.

Question: Compute the horizontal and vertical components of force at pin B. The belt is subjected to a tension of T=100 N and passes over each of the three pulleys.
[A].

Bx = 0 N, By = 141.4 N

[B].

Bx = -15.89 N, By = 120.7 N

[C].

Bx = 20.7 N, By = 157.3 N

[D].

Bx = 0, By = 100.0 N

Answer: Option B

Explanation:

No answer description available for this question.

EXPLORE : DISCOVER

Question: EXPLORE : DISCOVER
[A].

read : skim

[B].

research : learn

[C].

write : print

[D].

think : relate

Answer: Option B

Explanation:

One explores to discover; one researches to learn.

The capillary tube is not used in large capacity refrigeration systems because

Question: The capillary tube is not used in large capacity refrigeration systems because
[A].

cost is too high

[B].

capacity control is not possible

[C].

it is made of copper

[D].

required pressure drop can not be achieved

Answer: Option B

Explanation:

No answer description available for this question.

In a refrigeration system, the expansion device is connected between the

Question: In a refrigeration system, the expansion device is connected between the
[A].

compressor and condenser

[B].

condenser and receiver

[C].

receiver and evaporator

[D].

evaporator and compressor

Answer: Option C

Explanation:

No answer description available for this question.

The capacity of the cooling tower and spray ponds __________ as the wet bulb temperature of air decreases.

Question: The capacity of the cooling tower and spray ponds __________ as the wet bulb temperature of air decreases.
[A].

increases

[B].

decreases

Answer: Option A

Explanation:

No answer description available for this question.