If a Nyquist plot of G (jω) H (jω) for a closed loop system passes through (-2, j0) point in GH plane, what would be the value of gain margin of the system in dB?

Question:

If a Nyquist plot of G (jω) H (jω) for a closed loop system passes through (-2, j0) point in GH plane, what would be the value of gain margin of the system in dB?

A.

0 db

B.

2.0201 db

C.

4 db

D.

6.0205 db

Answer» d. 6.0205 db

Note: The above multiple-choice question is for all general and Competitive Exams in India

If a Nyquist plot of G (jω) H (jω) for a closed loop system passes through (-2, j0) point in GH plane, what would be the value of gain margin of the system in dB? Read More »

» Control System Engineering (CSE) solved MCQs

Nichol’s chart:

Question:

Nichol’s chart:

A.

constant gain and constant phase shift loci of the closed-loop system.

B.

plot of loop gain with the variation in frequency

C.

circles of constant gain for the closed loop transfer function

D.

circles of constant phase shift for the closed loop transfer function

Answer» b. plot of loop gain with the variation in frequency

Note: The above multiple-choice question is for all general and Competitive Exams in India

Nichol’s chart: Read More »

» Control System Engineering (CSE) solved MCQs

high temperature corrosion of a carbon stee; can be a problem at a temperature above

Question:

high temperature corrosion of a carbon stee; can be a problem at a temperature above

A.

500 oc

B.

1000 oc

C.

1500 oc

D.

none of the above

Answer» a. 500 oc

Note: The above multiple-choice question is for all general and Competitive Exams in India

high temperature corrosion of a carbon stee; can be a problem at a temperature above Read More »

» Material Science solved MCQs

one of the following is a preventive measure to control corrosion fatigue failure

Question:

one of the following is a preventive measure to control corrosion fatigue failure

A.

eliminate cyclic stresses

B.

reduces stress concentratio n

C.

obtain a smooth and shiny surface on the metal

D.

all of the above

Answer» d. all of the above

Note: The above multiple-choice question is for all general and Competitive Exams in India

one of the following is a preventive measure to control corrosion fatigue failure Read More »

» Material Science solved MCQs

A system has poles at 0.01 Hz, 1 Hz and 80Hz, zeroes at 5Hz, 100Hz and 200Hz. The approximate phase of the system response at 20 Hz is :

Question:

A system has poles at 0.01 Hz, 1 Hz and 80Hz, zeroes at 5Hz, 100Hz and 200Hz. The approximate phase of the system response at 20 Hz is :

A.

-90°

B.

0° c) 90°

C.

d) -180°

Answer» a. -90°

Note: The above multiple-choice question is for all general and Competitive Exams in India

A system has poles at 0.01 Hz, 1 Hz and 80Hz, zeroes at 5Hz, 100Hz and 200Hz. The approximate phase of the system response at 20 Hz is : Read More »

» Control System Engineering (CSE) solved MCQs