Synchronous Motors

A synchronous motor is running with normal excitation. When the load is increased, the armature current drawn by it increases because

A synchronous motor is running with normal excitation. When the load is increased, the armature current drawn by it increases because

A. speed of the motor is reduced
B. power factor is decreased
C. Eb (back e.m.f.) becomes less than V (applied voltage)
D. Er (net resultant voltage) in armature is increased
E. none of the above

A synchronous motor is running with normal excitation. When the load is increased, the armature current drawn by it increases because Read More »

Synchronous Motors

If in a synchronous motor, driving a given mechanical load and drawing current at a leading power factor from constant voltage supply its field excitation is increased, its power factor

If in a synchronous motor, driving a given mechanical load and drawing current at a leading power factor from constant voltage supply its field excitation is increased, its power factor

A. will become more
B. will become less
C. will remain unchanged
D. none of the above.

If in a synchronous motor, driving a given mechanical load and drawing current at a leading power factor from constant voltage supply its field excitation is increased, its power factor Read More »

Synchronous Motors

If excitation of a synchronous motor running with a constant load is decreased from its normal value, ignoring effects of armature reaction, it leads to____________?

If excitation of a synchronous motor running with a constant load is decreased from its normal value, ignoring effects of armature reaction, it leads to____________?

A. increase in both armature current and power factor angle
B. increase in back e.m.f. but decrease in armature current
C. increase in both armature current and power factor which is lagging
D. increase in torque angle but decrease in back e.m.f.

If excitation of a synchronous motor running with a constant load is decreased from its normal value, ignoring effects of armature reaction, it leads to____________? Read More »

Synchronous Motors

While starting a salient pole synchronous motor by induction motor action and connecting field discharge resistance across field, starting and accelerating torque is produced by_____________?

While starting a salient pole synchronous motor by induction motor action and connecting field discharge resistance across field, starting and accelerating torque is produced by_____________?

A. induction motor torque in field winding
B. induction motor torque in damper winding
C. eddy current and hysteresis torque in pole faces
D. reHetance motor torque due to saliency of the rotor
E. all of the above methods

While starting a salient pole synchronous motor by induction motor action and connecting field discharge resistance across field, starting and accelerating torque is produced by_____________? Read More »

Synchronous Motors

A synchronous motor installed at the receiving end substation operates with such an excitation that it takes power at lagging power factor. Now if the applied voltage of the synchronous motor goes down, the power factor of the synchronous motor will___________?

A synchronous motor installed at the receiving end substation operates with such an excitation that it takes power at lagging power factor. Now if the applied voltage of the synchronous motor goes down, the power factor of the synchronous motor will___________?

A. remain same
B. go down
C. improve
D. none of the above

A synchronous motor installed at the receiving end substation operates with such an excitation that it takes power at lagging power factor. Now if the applied voltage of the synchronous motor goes down, the power factor of the synchronous motor will___________? Read More »

Synchronous Motors