Process Control and Instrumentation

Find the ultimate gain and frequency for a proportional controller in the case of a process having the transfer function Gp(s) = 1/(4s + 1)(2s + 1)(s + 1) ?

Find the ultimate gain and frequency for a proportional controller in the case of a process having the transfer function Gp(s) = 1/(4s + 1)(2s + 1)(s + 1) ?

A. w = 1/√14, Kc = 45/7 √14
B. w = √(7/6), Kc = 46/3
C. w = 1, Kc = 13
D. w = √(7/8), Kc = 45/4

Find the ultimate gain and frequency for a proportional controller in the case of a process having the transfer function Gp(s) = 1/(4s + 1)(2s + 1)(s + 1) ? Read More »

Process Control and Instrumentation

Normal mercury thermometer can be used to measure a temperature of about 300°C. However, its maximum temperature measurement range can be increased upto about 500°C by__________________?

Normal mercury thermometer can be used to measure a temperature of about 300°C. However, its maximum temperature measurement range can be increased upto about 500°C by__________________?

A. Filling nitrogen under pressure in the stem
B. Increasing the diameter of the tube
C. Using steel tube in place of glass tube
D. Accounting for the tube expansion

Normal mercury thermometer can be used to measure a temperature of about 300°C. However, its maximum temperature measurement range can be increased upto about 500°C by__________________? Read More »

Process Control and Instrumentation

Stabilising time for the controllers is the time required for the response to reach _____________ percent of its ultimate value?

Stabilising time for the controllers is the time required for the response to reach _____________ percent of its ultimate value?

A. 63.2
B. 87.5
C. 95
D. 100

Stabilising time for the controllers is the time required for the response to reach _____________ percent of its ultimate value? Read More »

Process Control and Instrumentation

Platinum resistance thermometer can be used upto antimony point which is ____________ °C, and is the temperature of equilibrium between solid antimony & liquid antimony at normal atmospheric pressure?

Platinum resistance thermometer can be used upto antimony point which is ____________ °C, and is the temperature of equilibrium between solid antimony & liquid antimony at normal atmospheric pressure?

A. 961.93
B. 630.74
C. 1064.43
D. 1261.93

Platinum resistance thermometer can be used upto antimony point which is ____________ °C, and is the temperature of equilibrium between solid antimony & liquid antimony at normal atmospheric pressure? Read More »

Process Control and Instrumentation