Which of the following is not the triple point of water ?

August 24, 2021March 5, 2019 by admin
Which of the following is not the triple point of water ?

A. 32°R
B. 273°K
C. 492°R
D. 32°F

Categories Process Control and Instrumentation

Flow rate through an orifice is _____________ the pressure differential?

August 24, 2021March 5, 2019 by admin
Flow rate through an orifice is _____________ the pressure differential?

A. Proportional to
B. Inversely proportional to the square root of
C. Proportional to the square root of
D. Inversely proportional to the square of

Categories Process Control and Instrumentation

What is the ratio of output amplitude to input amplitude for a sinusoidal forcing function in a first order system ?

August 24, 2021March 5, 2019 by admin
What is the ratio of output amplitude to input amplitude for a sinusoidal forcing function in a first order system ?

A. 1
B. > 1
C. < 1
D. None of these

Categories Process Control and Instrumentation

Continuous shell temperature measurement in a liquid-liquid heat exchanger is done by a __________________?

August 24, 2021March 5, 2019 by admin
Continuous shell temperature measurement in a liquid-liquid heat exchanger is done by a __________________?

A. Thermocouple
B. Resistance thermometer
C. Mercury in glass thermometer
D. Vapor pressure thermometer

Categories Process Control and Instrumentation

Time constant is the __________________?

August 24, 2021March 5, 2019 by admin
Time constant is the __________________?

A. Time taken by the controlled variable to reach 63.2% of its full change
B. Same as transportation lag
C. Same as dead time
D. Time required by the measured variable to reach 63.2% of its ultimate change

Categories Process Control and Instrumentation

The maximum service temperature for fibre glass used as thermocouple wire insulation material is __________ °C?

August 24, 2021March 5, 2019 by admin
The maximum service temperature for fibre glass used as thermocouple wire insulation material is __________ °C?

A. 250
B. 500
C. 750
D. 1000

Categories Process Control and Instrumentation

A bimetallic thermometer as compared to industrial mercury in glass thermometer has almost the same_________________?

August 24, 2021March 5, 2019 by admin
A bimetallic thermometer as compared to industrial mercury in glass thermometer has almost the same_________________?

A. Temperature measuring range (- 40°C to 450°C)
B. Accuracy (± 1% of span)
C. Speed of response
D. All a, b & c

Categories Process Control and Instrumentation

Operating range of a temperature measuring instrument is 800 to 1600°C. It could be a/an _____________ pyrometer?

August 24, 2021March 5, 2019 by admin
Operating range of a temperature measuring instrument is 800 to 1600°C. It could be a/an _____________ pyrometer?

A. Radiation
B. Optical
C. Photoelectric
D. None of these

Categories Process Control and Instrumentation

Positioning controllers are used for _______________?

August 24, 2021March 5, 2019 by admin
Positioning controllers are used for _______________?

A. Low loads
B. Temperature changes
C. High loads
D. Flow rate changes

Categories Process Control and Instrumentation

Reset rate is the another term used for ____________ time?

August 24, 2021March 5, 2019 by admin
Reset rate is the another term used for ____________ time?

A. Dead
B. Integral
C. Derivative
D. None of these

Categories Process Control and Instrumentation