Our website is made possible by displaying online advertisements to our visitors. Please consider supporting us by whitelisting our website.

Process Control and Instrumentation

Suppose that the gain, time constant and dead time of a process with the following transfer function: Gc(s) = 10 exp( – 0.1s)/(0.5s + 1) are known with a possible error of ± 20% of their values. The largest permissible gain Kc of a proportional controller needs to be calculated below taking the values of process gain, time constant and dead time as________________?

Suppose that the gain, time constant and dead time of a process with the following transfer function: Gc(s) = 10 exp( – 0.1s)/(0.5s + 1) are known with a possible error of ± 20% of their values. The largest permissible gain Kc of a proportional controller needs to be calculated below taking the values of process gain, time constant and dead time as________________?

A. 8, 0.6, 0.08
B. 12, 0.6, 0.12
C. 8, 0.6, 0.12
D. 12, 0.4, 0.08

Suppose that the gain, time constant and dead time of a process with the following transfer function: Gc(s) = 10 exp( – 0.1s)/(0.5s + 1) are known with a possible error of ± 20% of their values. The largest permissible gain Kc of a proportional controller needs to be calculated below taking the values of process gain, time constant and dead time as________________? Read More »

Process Control and Instrumentation

The frequency response of a dynamic element shows a constant magnitude ratio at all frequencies. The element exhibits a negative phase shift at all frequencies. The absolute value of the phase shift increases linearly with frequency. The element has the transfer function ?

The frequency response of a dynamic element shows a constant magnitude ratio at all frequencies. The element exhibits a negative phase shift at all frequencies. The absolute value of the phase shift increases linearly with frequency. The element has the transfer function ?

A. e-ηS
B. (T1S + 1)/(T2S + 1)
C. (T1S/(T2S + 1)
D. (T1S + 1)/(T2S

The frequency response of a dynamic element shows a constant magnitude ratio at all frequencies. The element exhibits a negative phase shift at all frequencies. The absolute value of the phase shift increases linearly with frequency. The element has the transfer function ? Read More »

Process Control and Instrumentation

The experimental response of the controlled variable y(t) for a step change of magnitude ‘P’ in the manipulated variable x(t) is shown below: The appropriate transfer function of the process is_________________?

The experimental response of the controlled variable y(t) for a step change of magnitude ‘P’ in the manipulated variable x(t) is shown below: The appropriate transfer function of the process is_________________?

A. (Q/P) e-(Q/R)S/(TdS + 1)
B. (Q/R) e-TdS/(Q/P) (S + 1)
C. (Q/P) e-TdS/(Q/R) (S + 1)
D. (Q/R) e-(P/Q)S/(TdS + 1)

The experimental response of the controlled variable y(t) for a step change of magnitude ‘P’ in the manipulated variable x(t) is shown below: The appropriate transfer function of the process is_________________? Read More »

Process Control and Instrumentation