Skip to content
AnsweringExams.Com
  • Home
  • Contact Us / Report Error
  • Disclaimer

Design of Steel Structures

The forces acting on the web splice of a plate girder are__________________?

August 15, 2021January 20, 2019 by admin
The forces acting on the web splice of a plate girder are__________________?

A. axial forces
B. shear and axial forces
C. shear and bending forces
D. axial and bending forces

Categories Design of Steel Structures

Bearing stiffeners are provided at________________?

August 15, 2021January 20, 2019 by admin
Bearing stiffeners are provided at________________?

i) the supports
ii) the mid span
iii) the point of application of concentrated loads

The correct answer is?
A. only (i)
B. both (i) and (ii)
C. both (i) and (iii)
D. (i), (ii) and (iii)

Categories Design of Steel Structures

The maximum spacing of vertical stiffeners is_________________?

August 15, 2021January 20, 2019 by admin
The maximum spacing of vertical stiffeners is_________________?

A. 1.33 d
B. 1.25 d
C. 1.5 d
D. 1.75 d
where d is the distance between flange angles

Categories Design of Steel Structures

The maximum permissible span of asbestos cement sheets is______________________?

August 15, 2021January 20, 2019 by admin
The maximum permissible span of asbestos cement sheets is______________________?

A. 650 mm
B. 810 mm
C. 1250 mm
D. 1680 mm

Categories Design of Steel Structures

The minimum thickness of plates in a steel stack should be___________________?

August 15, 2021January 20, 2019 by admin
The minimum thickness of plates in a steel stack should be___________________?

A. 4 mm
B. 5 mm
C. 6 mm
D. 8 mm

Categories Design of Steel Structures

To minimize the total cost of a roof truss, the ratio of the cost of truss to the cost of purlins shall be_______________?

August 15, 2021January 20, 2019 by admin
To minimize the total cost of a roof truss, the ratio of the cost of truss to the cost of purlins shall be_______________?

A. 1
B. 2
C. 3
D. 4

Categories Design of Steel Structures

For the buildings having a low permeability, the internal wind pressure acting normal to the wall and roof surfaces is taken as__________________?

August 15, 2021January 20, 2019 by admin
For the buildings having a low permeability, the internal wind pressure acting normal to the wall and roof surfaces is taken as__________________?

A. zero
B. ±0.2p
C. ± 0.5 p
D. ±0.7p
where p is basic wind pressure

Categories Design of Steel Structures

The live load for a sloping roof with slope 15°, where access is not provided to roof, is taken as_______________?

August 15, 2021January 20, 2019 by admin
The live load for a slog roof with slope 15°, where access is not provided to roof, is taken as_______________?

A. 0.65 kN/m2
B. 0.75 kN/m2
C. 1.35 kN/m2
D. 1.50 kN/m2

Categories Design of Steel Structures

The basic wind speed is specified at a height ‘h’ above mean ground level in an open terrain. The value of’h’ is__________________?

August 15, 2021January 20, 2019 by admin
The basic wind speed is specified at a height ‘h’ above mean ground level in an open terrain. The value of’h’ is__________________?

A. 10 m
B. 20 m
C. 25 m
D. 50 m

Categories Design of Steel Structures

The external wind pressure acting on a roof depends on__________________?

August 15, 2021January 20, 2019 by admin
The external wind pressure acting on a roof depends on__________________?

A. degree of permeability of roof
B. slope of roof
C. both (A) and (B)
D. none of the above

Categories Design of Steel Structures
Older posts
Newer posts
← Previous Page1 Page2 Page3 … Page11 Next →
© 2025 AnsweringExams.Com • Built with GeneratePress