One kilogram of water at 0°C is changed to superheated steam of one atm pressure and 300° C. The major heat consumption in the process will be to

Question: One kilogram of water at 0°C is changed to superheated steam of one atm pressure and 300° C. The major heat consumption in the process will be to
[A].

heat the water from 0°C to 100°C.

[B].

evaporate the water.

[C].

to superheat the steam.

[D].

data insufficient, can’t be predicted

Answer: Option B

Explanation:

No answer description available for this question.

One kilogram of water at 0°C is changed to superheated steam of one atm pressure and 300° C. The major heat consumption in the process will be to Read More »

CHEMICAL ENGINEERING, Heat Transfer

If a single tube pass heat exchanger is converted to two pass, then for the same flow rate, the pressure drop per unit length in tube side will

Question: If a single tube pass heat exchanger is converted to two pass, then for the same flow rate, the pressure drop per unit length in tube side will
[A].

increase by 1.8 times

[B].

decrease by 22

[C].

increase by 216

[D].

remain unchanged

Answer: Option C

Explanation:

No answer description available for this question.

If a single tube pass heat exchanger is converted to two pass, then for the same flow rate, the pressure drop per unit length in tube side will Read More »

CHEMICAL ENGINEERING, Heat Transfer

A single pass air heater is connected to a two pass unit. For the air flow rate and other conditions remaining the same, the film heat transfer co-efficient for air will vary in the ratio of

Question: A single pass air heater is connected to a two pass unit. For the air flow rate and other conditions remaining the same, the film heat transfer co-efficient for air will vary in the ratio of
[A].

2

[B].

20.8

[C].

20.2

[D].

20.5

Answer: Option B

Explanation:

No answer description available for this question.

A single pass air heater is connected to a two pass unit. For the air flow rate and other conditions remaining the same, the film heat transfer co-efficient for air will vary in the ratio of Read More »

CHEMICAL ENGINEERING, Heat Transfer

For evaporation of viscous solution in a multiple effect evaporator, the prefered feeding scheme is

Question: For evaporation of viscous solution in a multiple effect evaporator, the prefered feeding scheme is
[A].

forward

[B].

backward

[C].

parallel

[D].

none of these

Answer: Option B

Explanation:

No answer description available for this question.

For evaporation of viscous solution in a multiple effect evaporator, the prefered feeding scheme is Read More »

CHEMICAL ENGINEERING, Heat Transfer

For the same heat load and mass flow rate in the tube side of a shell and tube heat exchanger, one may use multipass on the tube side, because it

Question: For the same heat load and mass flow rate in the tube side of a shell and tube heat exchanger, one may use multipass on the tube side, because it
[A].

decreases the pressure drop.

[B].

decreases the outlet temperature of cooling medium.

[C].

increases the overall heat transfer coefficient.

[D].

none of these.

Answer: Option C

Explanation:

No answer description available for this question.

For the same heat load and mass flow rate in the tube side of a shell and tube heat exchanger, one may use multipass on the tube side, because it Read More »

CHEMICAL ENGINEERING, Heat Transfer

You type debug ip rip on your router console and see that 172.16.10.0 is being advertised to you with a metric of 16. What does this mean?

Question: You type debug ip rip on your router console and see that 172.16.10.0 is being advertised to you with a metric of 16. What does this mean?
[A].

The route is 16 hops away.

[B].

The route has a delay of 16 microseconds.

[C].

The route is inaccessible.

[D].

The route is queued at 16 messages a second.

Answer: Option C

Explanation:

You cannot have 16 hops on a RIP network by default. If you receive a route advertised with a metric of 16, this means it is inaccessible.

You type debug ip rip on your router console and see that 172.16.10.0 is being advertised to you with a metric of 16. What does this mean? Read More »

Ip Routing, Networking